Abstract
This study used contrast-enhanced ultrasound (CEUS) to evaluate changes in renal cortical blood perfusion after percutaneous transluminal renal angioplasty and stenting (PTRAS) for severe renal artery stenosis (RAS) (≥70%). CEUS was performed in 21 patients with 24 severe RASs that underwent PTRAS. Renal cortical perfusion was quantitatively evaluated by comparing time intensity curve (TIC) parameters for SonoVue (Bracco, Milan, Italy) contrast enhancement, including peak intensity (PI), time to peak (TTP), mean transmit time (MTT), curve ascending slope (S), area under the curve (AUC), AUC-wash-in and AUC-wash-out. The parameters PI, TTP, MTT and S differed significantly between the pre-intervention and post-intervention TIC analysis (p < 0.05). Of the 24 pre-intervention curve appearances, 58.3% (14/24) improved after operation. The PI difference correlated positively with the estimated glomerular filtration rate difference (r = 0.433, p < 0.05). In conclusion, changes in some ultrasound perfusion parameters on CEUS and the shape of the TIC can be used to quantitatively and intuitively evaluate renal cortical blood perfusion change after PTRAS.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.