Abstract

A simple, quick, and non-destructive way to measure deposited Cu, used for back contact formation, and thickness of CdS and CdTe layers in the device is desirable for manufacturing process control. A simple X-ray Fluorescence (XRF) system was investigated for these measurements. Experiments show that 5 min. polychromatic XRF spectra can be used to measure CdTe and CdS thickness, and accurate 30 sec. measurements are possible. Statistical integrity of Cu XRF measurements was investigated. XRF measurements are able to differentiate Cu concentrations within 10% of nominal, making it useful for process control. A description of a new, improved in-line R&D deposition system is also presented. Thermal modeling results show the new NiCr wire based heating system will reach desired operating temperatures while providing opportunities for improved temperature uniformity and energy usage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.