This study derived the five parameters in Johnson-Cook equation of CP titanium Gr2. Quasi-static and dynamic compression tests were designed to measure mechanical properties at strain rates of 10-3s-1 and 6000s-1. In order to secure the validity of tested data, a novel fixture was proposed to reduce the displacement measurement error in MTS testing system and the signal processing procedure of compressive split Hopkinson pressure bar for the present study was demonstrated. With the tested data and calculated adiabatic heating temperature rise, parameters A, B, n, m, C have been derived based on mathematical deduction and solve. It was found that the constructed constitutive model fit the tested data well and was able to restore the yield strength value at high strain rate.