Abstract
An optode was designed for an indirect determination of ascorbic acid by using neocuproine, which has been coated on transparent triacetylcellulose film as a membrane. The proposed method is based on the oxidation of ascorbic acid to dehydroascorbic acid with the Cu(II) and neocuproine reagent. The increase in the absorbance value of the optode at the maximum wavelength of 455 nm was related to the ascorbic acid concentration in aqueous samples. The sensitivity of the method was improved by using room-temperature ionic liquid, [C(8)MIM][PF(6)]. The linear dynamic range for the determination of ascorbic acid was 7.4 × 10(-5) - 3.5 × 10(-3) mol L(-1) with a limit of detection of 2.2 × 10(-5) mol L(-1) (n = 10) and a response time range of 6.0 - 8.0 min. The optode was successfully applied for the determination of ascorbic acid in orange juice.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.