Abstract

We have constructed a stochastic model of a water supply network with leaks, which, compared to the previously proposed models (excluding leaks), more adequately describes the processes of transportation and water distribution in water supply systems. Mathematical modeling of water supply networks is associated with difficulties related to the huge dimensionality of actual water supply networks, limited information resources and operational data, which does not make it possible to assess parameters of the technological equipment and structure of a water supply network adequately enough. Therefore, an equivalent scheme is built for an actual water supply network based on its dictation points, which is then used for subsequent calculations. The task on building a scheme for an equivalent water supply network consists of three problems: identification of the structure, parameters, and state of a water supply network. The proposed method for leaks detection is based on the comparison of change in the magnitude of head at pumping stations and at the dictation points of a water supply network. Based on the stochastic model of a water supply network with leaks, we have constructed a method for calculating the magnitude of leaks, which implies the following: by knowing the head of water at the nodes of an equivalent water supply network and the approximate diameters of leaks at nodes, new values of heads at nodes of the equivalent water supply network are calculated. Then we again compute the magnitude of a leak by knowing the new head at the node and the diameter of the leaks. Upon completion of several such iterations, a conclusion is drawn on that starting at a certain step the magnitude of leaks and the heads at the nodes of the equivalent water supply network stop changing. By knowing the magnitude of leaks and head at each node within the equivalent water supply network, we determine the actual diameter of fistulas at each node. The proposed method for calculating the magnitude of leaks does not require financial costs or the use of additional equipment; it could be used by water utilities to detect and calculate the magnitude of leaks

Highlights

  • One of the most acute issues in water supply systems is water leaks from damaged pipelines and shut-off fittings due to their wear

  • If there are no leaks in the equivalent water supply network (EWN), the heads at both pumping stations would grow by the same magnitude, by 1 meter (Fig. 6)

  • The task on constructing a scheme of an equivalent water supply network included the problem of identifying the structure, parameters, and condition of a water supply network

Read more

Summary

Introduction

One of the most acute issues in water supply systems is water leaks from damaged pipelines and shut-off fittings due to their wear. Cracks, and minor defects in a water pipeline are difficult to detect, and even more difficult to eliminate, without a major overhaul. In addition to the loss of water, leaks often destroy underground communications, cause failures of bridges and pavements, washing the foundations of buildings, washing up cable networks, result in subsidence of tram tracks, etc. This leads to accidents and, in turn, causes damage repair costs. Electricity costs are increasing to compensate consumers for the undelivered amount of water and reagents to purify it

Objectives
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.