Abstract

A new carbon paste electrode based on the use of an ionic liquid as the binder is introduced. The composite electrode consists of graphite and n-octylpyridinium hexafluorophosphate (an ionic liquid). The behavior of the n-octylpyridinium hexafluorophosphate carbon paste electrode (OPFP-CPE) towards [Fe(CN)6]3−/4− was tested. This novel electrode has conductivity similar to glassy carbon electrode (GCE). It shows low background current and well defined voltammograms for the [Fe(CN)6]3−/4−. The oxidation of nitrite was studied on the OPFP-CPE in aqueous solution using cyclic voltammetry (CV), differential pulse voltammetry (DPV), and chronoamperometry (CA). The proposed method was used for determination of nitrite in food samples (ham sausage) containing nitrite. Nitrite can be determined in the ranges of 1.0 × 10−4 to 1.0 × 10−3 M by CV, 1.0 × 10−6 to 2.0 × 10−4 M by DPV and 7.6 × 10−6 to 1.4 × 10−4 M by CA, with the detection limits of 3.0 × 10−5 M, 1.0 × 10−7 M, and 4.0 × 10−7 M (calculated by 3σ) for CV, DPV, and CA, respectively. The recovery of spiked nitrite to the ham sausage extract was from 90.00% to 109.76%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.