Abstract
The aim of this study was to establish which of seven factors influence the adhesion strength and hence bacterial transfer between biofilms containing Listeria monocytogenes (pure and two-species biofilms) and tryptone soya agar (TSA) as a solid organic surface. The two-species biofilms were made of L. monocytogenes and one of the following species of bacteria: the nonpathogenic organisms Kocuria varians, Pseudomonas fluorescens, and Staphylococcus sciuri and CCL 63, an unidentified gram-negative bacterium isolated from the processing plant environment. We used biofilms prepared under conditions simulating open surfaces in meat-processing sites. The biofilm's adhesion strength and population were evaluated by making 12 contacts on a given whole biofilm (4.5 cm(2)), using a new slice of a sterilized TSA cylinder for each contact, and plotting the logarithm CFU . cm(-2) detached by each contact against the contact number. Three types of detachment kinetics were observed: biphasic kinetics, where the first slope may be either positive or negative, and monophasic kinetics. The bacteria that resisted a chlorinated alkaline product and a glutaraldehyde- and quaternary ammonium-based disinfectant had greater adhesion strengths than those determined for untreated biofilms. One of the four non-Listeria strains studied, Kocuria varians CCL 56, favored both the attachment and detachment of L. monocytogenes. The stainless steel had smaller bacterial populations than polymer materials, and non-Listeria bacteria adhered to it less strongly. Our results helped to evaluate measures aimed at controlling the immediate risk, linked to the presence of a large number of CFU in a foodstuff, and the delayed risk, linked to the persistence of L. monocytogenes and the occurrence of slightly contaminated foods that may become dangerous if L. monocytogenes multiplies during storage. Cleaning and disinfection reduce the immediate risk, while reducing the delayed risk should be achieved by lowering the adhesion strength, which the sanitizers used here cannot do at low concentrations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.