Abstract
The deuterium washout technique of measuring tissue blood flow is based upon NMR detection of HOD (administered as D2O saline, but typically detected as HOD because of rapid proton-deuteron exchange) as a freely diffusible tracer. Though this method is coming into more general use, it has not yet been rigorously validated in vivo against an accepted, independent measure of tissue blood flow. To this end, simultaneous radiolabeled microsphere and HOD washout blood flow measurements were made in rat gastrocnemius muscle. D2O saline was administered either intramuscularly or intraarterially (near the aortic bifurcation), and the sciatic nerve was electrically stimulated to increase the muscle blood flow rate. Over a range of flows of 2 to 80 ml/(100 g.min), comparison of microsphere and HOD washout measurements showed good agreement, with r = 0.92 (n = 16) for intramuscular administration and r = 0.91 (n = 12) for intraarterial administration. These data strongly suggest that the HOD washout technique provides accurate blood flow measurements in skeletal muscle.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.