Abstract

AbstractA design synthesis procedure is developed for preliminary design of utility systems. Given known steam sources (waste heat and auxiliary boilers) and sinks (heating, process injection, and driver horsepower needs), the algorithm determines the optimal header pressure levels, the distribution of steam turbines in the network, and the steam flows between all devices so as to maximize the real work recovered from the sources. Any number of pressure levels can be accommodated at only modest increase in computational effort.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.