Abstract

In this study, a Computational Fluid Dynamics (CFD) approach using Ansys Fluent 15.0 and FLIC software was employed to simulate the combustion process of a 750 t/d grate-type waste incinerator. The objective was to assess the performance of Selective Non-Catalytic Reduction (SNCR) technology in reducing nitrogen oxide (NOx) emissions. Two-stage simulations were conducted, predicting waste combustion on the bed and volatile matter combustion in the furnace. The results effectively depicted the temperature and gas concentration distributions on the bed surface, along with the temperature, velocity, and composition distributions in the furnace. Comparison with field data validated the numerical model. The findings serve as a reference for optimizing large-scale incinerator operation and parameter design through CFD simulation.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call