Abstract
This paper investigated the influence of embedding pseudoelastic shape memory alloy within the external bonded patch made up of glass fibers on the compression after impact response of adhesively bonded external patch repaired glass/epoxy composite laminates. Unsymmetrical patch repair was employed in the current studies. Three innovative pseudoelastic shape memory alloy configurations (straight wired, meshed and anchored) were embedded inside the patch and the changes in high-velocity impact response and damage tolerance at four impact velocities (70, 85, 95, 105 m/s) were compared with the conventional glass/epoxy (glass fiber-reinforced polymer) patch. Anchored specimens showed the best response by improving the compressive strength by 25% under non-impacted conditions and restoring it by 88%, 77%, 29%, and 28% at the impact velocity of 70, 85, 95, and 105 m/s, respectively, in comparison to the conventional normal specimens.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.