Abstract

In this work, Cu(II)-exchanged clinoptilolite nanoparticles (Cu(II)-NCL) were prepared and characterized by FTIR, BET, XRD and TEM techniques. The obtained Cu(II)-NCL was then used for the modification of carbon paste electrode (CPE). The resulted Cu(II)-NCL/CPE was finally used for the voltammetric determination of amoxicillin (AMX). The best voltammetric response was obtained by the electrode containing 20% of the modifier in 0.05molL−1 NaCl at pHs 2.2 and 7.2. The electrode showed a linear response in the concentration range of 4.0×10−8–1.0×10−4molL−1 AMX with a detection limit of 2.0×10−8molL−1 in square wave voltammetry. The electrode showed good repeatability, reproducibility, long life time confirmed by statistical tests. The electrode had also good selectivity together with good applicability in determination of AMX in urine and pharmaceutical tablets as real samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.