Abstract
In this work, parameter extraction methodology for the BSIM industry standard high-voltage (HV) device compact model is presented. An extraction procedure covers entire range of operation, including weak inversion to strong inversion region, low and high drain biases, and multiple body biases with temperature effects. The extraction procedure is validated with experimental and numerical simulation data for several configurations of HV devices, including geometric variations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.