Abstract

This paper deals with the output voltage tracking control problem of three-phase inverters with multiple disturbances (including parametric perturbations of filter, abrupt disturbances caused by load switching, and harmonic disturbances brought by unbalanced loads and nonlinear loads). Some novel composite disturbance observers are designed to estimate the above multiple disturbances. Based on the disturbance estimates and backstepping control technique, an innovative feedforward-feedback composite tracking control scheme is proposed. The new control scheme has a good disturbance rejection ability and ensures good tracking performances. In the meantime, rigorous stability proof is presented. Simulation and experimental results are illustrated to verify the feasibility and effectiveness of the proposed control scheme.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.