Abstract

To describe all post-insertion complications involving most used intravascular access, and to determine whether the use of a new-generation transparent dressing (3M™ IV Advanced) might reduce their number and impact on ICU patient outcomes. Patients older than 18, with an expected length of stay ≥48h and requiring at least one central venous catheter (CVC), arterial catheter (AC), haemodialysis catheter (HDC), pulmonary arterial catheters (PAC) or peripheral venous catheter (PVC) were randomized into two groups: a new-generation transparent dressing, or the hospital's classical transparent dressing, and were followed daily for any infectious and non-infectious complications. Complications were graduated for severity by an independent international multicentre multidisciplinary panel of practitioners using a Delphi process. We included 628 patients, 2214 catheters (873 PVCs, 630 CVCs, 512 ACs and 199 HDCs and PACs) and 4836 dressings. Overall incidence rate was of 60.9/1000 catheter-days. The most common complication was dysfunction (34.6/1000 catheter-days), mainly for PVCs (16/1000 catheter-days) and ACs (12.9/1000 catheter-days). Infectious complications incidence rate in CVCs and ACs was of 14.5/1000, mostly due to colonization (14.2/1000 catheter-days). Thrombosis incidence was of 3.8/1000 catheter-days with severe and very severe complications in 16 cases (1.8/1000 catheter-days) and one thrombosis-related death. 3M™ IV Advanced dressing did not decrease the rate of catheters with at least a minor complication [57.37/1000 vs. 57.52/1000 catheter-days, HR 1.03, CI (0.84-1.27), p=0.81]. Incidence rates for each single complication remained equivalent: infectious [HR 0.93 (0.62-1.40), p=0.72], deep thrombosis [HR 0.90 (0.39-2.06), p=0.80], extravasation and phlebitis [HR 1.40 (0.69-2.82), p=0.35], accidental removal [1.07 (0.56-2.04), p=0.84] and dysfunction [HR 1.04 (0.80-1.35), p=0.79]. The ADVANCED study showed the overall risk of complications to intravascular catheters in ICU patients being dysfunction, infection and thrombosis. The 3M™ IV Advanced dressing did not decrease complication rates as compared to standard dressings.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.