Abstract
A comparison study of main parameter calculations: neutron wall loading (NWL), tritium breeding ratio (TBR), and nuclear heating, on a Korean fusion demonstration reactor (K-DEMO) neutronic analysis model using MCNP and ATTILA was performed to investigate the feasibility of using ATTILA for the main parameter calculations. The model was created by commercial CAD program (Pro-Engineer™) as a 22.5° sector of tokamak consisting of major components such as blankets, shields, divertors, vacuum vessels (VV), toroidal field (TF) coils, and others, which was directly imported into ATTILA by Parasolid file. The discretizing in space, angle, and energy variables were refined for application of the K-DEMO neutronic analysis model through an iterative process since these variables greatly impact on accuracy, solution times, and memory consumptions in ATTILA. The main parameter calculations using ATTILA and the result of comparison studies indicate that the NWL distributions by two codes were almost agreed within discrepancy of 3.3%; the TBR distribution using ATTILA was slightly bigger than MCNP with a difference 3.9%; the nuclear heating values on TF coils and VV were bigger than MCNP with relatively high difference (17% and 28%). As a result of comparisons, ATTILA shows close agreement with MCNP within reasonable discrepancy ranges (3.3–28%).
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have