Abstract
In the present study two shapes of ribs are used to improve the heat transfer coefficient. Ribs are constructed in two types viz a V–shaped rib and curve rib. The ribs are used to improve the heat transfer. Heat transfer and space reduction while maintaining the durability of the design and thus better cooling and thus avoiding thermal stress. Simulation numerical solution by CFD with ANSYS WORKBENCH R1 2021 with in established turbulence model standard K-ε was conducted. The experiment performed for two-phase flow of water (8 L/min) and for air (16.67 L/min) at constant rib temperature about 60 °C. The study results show that the enhancement percentage in curve rib is about 90.3% while in V-shaped rib is 88.27%. The results showed that the curve ribs was the optimum design.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.