Actually, cancer has gained a larger dimension and become a global public health problem. Radiotherapy (RT) is a neoplasia treatment and RT linear accelerators must undergo a strict dose quality control. Water or solid water phantoms can be used with this intuit. In recent years, radiochromic films with equivalent tissue composition have been widely used as dosimeters in the medical field. In this work the proposal was to analyze two distinct radiochromic film responses in water and solid water phantoms, a LINAC spectrum of 4MV beam. Solid water phantom, water phantom and EBT2 Radiochromic films were set in two distinct process of calibration. Films were exposed to a set of absorbed doses established by distinct monitor units (MU) specified in RT-center. Mathematical relations between the degree of red-intensity from digitized films and the absorbed dose for both methods were established. The coefficients of the polynomial function of the calibration curve were determined from the Origin software. The uncertainty of both processes was analyzed. The efficiency of the two calibration processes was set up. The adjustment of the calibration curve provided the coefficients of the second-order equation that relates the dose absorbed with the optical density of the film. The uncertainty regarding the calibration performed in water and solid water and the dose-error accuracy are in agreement with the literature. Both water and solid water were effective in calibration and can be used in routines of quality-control measurements. The results show that EBT2-radiochromic films are suitable to for dose-calibration in RT.

Highlights

  • The word cancer, in general, is used to designate a set of more than one hundred diseases that have in common the disordered growth of cells [1]

  • The results showed that EBT2-radiochromic films are suitable to for dose-calibration in RT

  • The measurements were performed by radiochromic films in two distinct environments, in water and solid water; both performed in the Linear accelerator (LINAC) model Clinac 6x SN11 of 4MV

Read more

Summary

INTRODUCTION

The word cancer, in general, is used to designate a set of more than one hundred diseases that have in common the disordered growth of cells [1]. RT employs high doses of radiation in the patient aiming the eradication of the malignant and occasional benign neoplasms The aim of this treatment modality is to deliver a precise dose to the tumor volume with minimal damage to neighboring tissues [3]. Phantoms of solid water should not be used in reference dosimetry for high energy photon beam; it has often being used in routine measures linked to quality assurance In this context, the goal of this study was to compare and evaluate the efficiency of the two calibration processes. The measurements were performed by radiochromic films in two distinct environments, in water and solid water; both performed in the Linear accelerator (LINAC) model Clinac 6x SN11 of 4MV In both processes, mathematical relationships between the level of film darkening and the absorbed dose were generated, compared and analyzed

MATERIALS AND METHODS
RESULTS AND DISCUSSION
CONCLUSION
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.