Abstract
A chemiluminescent-labeled DNA probe (Gen-Probe PACE 2 System) for detection of Chlamydia trachomatis in endocervical specimens was evaluated. For each specimen, tissue cell culture, direct immunofluorescent staining (DFA), and DNA probe assay were performed. Thirty of 318 (9.4%) specimens were positive for C. trachomatis. The sensitivities, specificities, and positive and negative predictive values of the DNA probe compared with cell culture were 93%, 98%, 85%, and 99%, respectively, and for DFA these same values were 81%, 99%, 83%, and 99%, respectively. The Gen-Probe PACE 2 System is a reliable method for the rapid detection of endocervical chlamydial infection.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.