Abstract

The Hen's Egg Test – Chorioallantoic Membrane (HET-CAM) is a valid alternative method used to assess the potential for eye irritation from chemicals. This method is the only one that mimics the conjunctivae of the eye and aims to semi-quantitatively evaluate the irritant potential of a chemical on the chorioallantoic membrane surrounding the chicken embryo in egg by observing the irritation effects on the membrane immediately after the pure or diluted chemical is applied. The purpose of this study was to compare the different protocols of the HET-CAM, the French and German protocols, by evaluating the eye irritation potential of surfactants. The comparison led to the optimization of the French protocol, generating an adapted one, to reduce subjectivity in the test evaluation, ensuring more accurate results and greater quality control. The comparison showed that there are no significant differences between the results obtained in the French and German protocols. HET-CAM is known to overestimate the results and to be able to accurately identify non-irritant products and it is a great candidate to be part of a Bottom-up test strategy. It also can be used in a battery of tests to completely replace rabbits.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call