Abstract

To determine the acceptability of the ClearSight™ system (Edwards Lifesciences Corp., Irvine, CA, USA) for continuous blood pressure monitoring during elective cardiac surgery compared with arterial catheterization. We enrolled 30 patients undergoing elective cardiac surgery in a prospective observational study. Blood pressure measurements were recorded every 10 sec intraoperatively. We determined agreement based on the Association for the Advancement of Medical Instrumentation (AAMI) recommendations. Statistical analysis included fixed bias (difference of measurements between methods), percentage error (accuracy between ClearSight measurement and expected measurement from arterial line), and interchangeability (ability to substitute ClearSight monitor without effecting overall outcome of analysis). We used a paired samples t test to compare the time required for placing each monitor. We found fixed bias in the differences between the ClearSight monitor and invasive arterial blood pressure measurement in systolic blood pressure (SBP; mean difference, 8.7; P < 0.001) and diastolic blood pressure (DBP; mean difference, -2.2; P < 0.001), but not in mean arterial pressure (MAP; mean difference, -0.5; P < 0.001). Bland-Altman plots showed that the means of the limits of agreement were greater than 5mm Hg for SBP, DBP, and MAP. The percentage errors for SBP, DBP, and MAP were lower than the cutoff we calculated from the invasive arterial blood pressure measurements. Average interchangeability rates were 38% for SBP, 50% for DBP, and 50% for MAP. Placement of the ClearSight finger cuff was significantly faster compared with arterial catheterization (mean [standard deviation], 1.7 [0.6] min vs 5.6 [4.1] min; P < 0.001). In this prospective observational study, we did not find the ClearSight system to be an acceptable substitute for invasive arterial blood pressure measurement in elective cardiac surgery patients according to AAMI guidelines. Nevertheless, based on statistical standards, there is evidence to suggest otherwise. ClinicalTrials.gov ( NCT05825937 ); first submitted 11 April 2023.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.