Abstract
This study compared the collateral tissue damage and incisional bridging with granulation tissue via histopathological examination following feline onychectomy performed by radiofrequency (RF) and carbon dioxide (CO(2)) laser. Two cats were euthanized, and their digits were harvested for histopathological evaluation on days 1, 3, and 7 post-onychectomy. Each digit was evaluated for total lesion width, total necrosis width, and degree of edema, hemorrhage, and inflammation. This study found few significant differences in collateral tissue damage between RF and CO(2) laser, but more incisional bridging by granulation tissue was noted with RF for feline onychectomies. These results indicate that RF for feline onychectomy is a reasonable alternative to CO(2) laser in regard to collateral tissue damage and bridging of the incision by granulation tissue. In addition, RF is not accompanied by the strict safety considerations and initial expense of acquisition of a CO(2) laser.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of the American Animal Hospital Association
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.