Abstract

Objective To compare and quantify the differences in size-specific dose estimates (SSDE) obtained by effective diameter and water-equivalent diameter from the central slice of the scan range in head CT examination. Methods A total of 111 consecutive adult patients who underwent head CT examination were enrolled in this study. All of CTDIvol values in the dose report were documented. The dataset was assigned into group A and group B, based on the individual size-dependent conversion factors (f) of effective diameter (deff) and water-equivalent diameter (dw) at the central slice multiplied by normalized volume computed tomography dose index (CTDIvol ) respectively. Body size, f and SSDE were calculated. With SSDEgross served as the reference level, the performance of SSDEdeff and SSDEdw was evaluated. Results Statistically significant differences were found in body size (t=47.587, P<0.05) and f(z=-9.242, P<0.05) between group A and group B. Statistically significant difference also existed in SSDE (t=-46.687, P<0.05), (56.20±2.66) and (53.49±2.48) mGy for group A and group B respectively. Strongly positive correlation was shown in body size (r=0.873, R2 =0.761) and SSDE (r=0.974, R2 =0.949) between group A and group B(all P<0.05). Positive correlation was also found between SSDEdeff and SSDEgross(r=0.900, R2 =0.809), SSDEdw and SSDEgross (r=0.904, R2 =0.817, all P<0.05). Mean absolute difference was 2.34 and 0.78 mGy, for SSDEdeffvs. SSDEgross and SSDEdwvs. SSDEgross respectively; mean absolute relative difference was 4.38%, 1.40%; root mean square difference was 1.17 mGy (2.17%), 1.06 mGy (1.91%). Interquartile range and full range of SSDEdeff and SSDEdw were 3.22 vs. 2.39 mGy, 13.65 vs. 12.48mGy, respectively. A less degree of variation was observed in SSDEdw than that in SSDEdeff. Conclusions SSDEdw values based on the water-equivalent diameter at the central slice of the scan range got better agreement with those derived from all slices, which could serve as a simpler and more valid indicator to represent the average value of size-specific dose estimates of the whole scan range in head CT examination. Key words: Head; CTDIvol; Effective diameter; Water equivalent diameter; Size-specific dose estimate

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.