Abstract
The location of dental implants and the choice of retentive attachments for implant-retained overdentures are selected based on clinician preference, expert opinion, or empirical information. Limited information is available regarding implant position and the effect on the retention and stability of 2-implant mandibular implant overdentures. The purpose of this investigation was to evaluate the effect of implant location on the invitro retention and stability of a simulated 2-implant-supported overdenture and to examine the differences among different attachment systems. A model that simulates a mandibular edentulous ridge with dental implants in positions that approximate tooth positions, and a cobalt-chromium cast framework attached to a universal testing machine was used to measure the peak load (N) required to disconnect the attachments. Four different types of attachments (Ball/Cap, ERA, Locator, and O-Ring) were used in sequence in various positions on the model to evaluate the effect of implant location on the retention and stability of a simulated 2-implant-retained overdenture. Means were calculated, and differences among the systems, directions, and groups were identified by using a repeated measured ANOVA (α=.05). For differences observed between measurements, the Bonferroni post hoc method at the 5% level of significance was used to determine the location and magnitude of difference. The interactions between the attachment system, direction of force, and implant location were statistically significant (P=.01). The vertical retention and horizontal stability of a simulated overdenture prosthesis increased with the distal implant location up to the second premolar, and the anteroposterior stability increased with distal implant location. The attachment type affected retention and stability differently by location. Ball attachments produced the highest levels of retention and stability, followed by Locator (pink), O-Ring, and ERA (orange). The retention and stability of a 2-implant simulated overdenture prosthesis is significantly affected by implant location (P=.01) and abutment type (P=.01).
Paper version not known (Free)
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.