Abstract

To help provide a clear understanding of the relative performance potential of HFCs (R-404A and R-410A) as compared to R-290 for walk-in refrigeration systems representing direct expansion commercial refrigeration systems with small charge, an experimental evaluation of the three refrigerants was investigated. To compare the environmental impact of refrigerants over the entire life cycle of fluid and equipment, including power consumption, the life cycle climate performance (LCCP) of the three refrigerants were evaluated based on measured data. The estimated LCCPs at various emission rates indicate that the LCCP of R-290 is always lower than that of R-404A. The LCCP of R-410A is lower than that of R-290 as long as the annual emission is kept below 10%. It was concluded that R-410A has less or equivalent environmental impact as compared to R-290 when safety (toxicity and flammability), environmental impact (climate change), cost and performance (capacity and COP) are considered.