Abstract
We report on comparison measurements for linewidths of test structures on chrome on glass photomasks by means of different types of light optical transmission microscopy and low voltage scanning electron microscopy (LVSEM). The investigated linewidth or critical dimension range was chosen to be between 0.3 micrometers and 5 micrometers on isolated and dense as well as clear and opaque line structures. After offset correction of the commercial i-line CD metrology tool we observed overall agreement between the results from light optical microscopy and the results from the LVSEM in the range of 20 nm. No significant polarization dependencies of transmitted light results were observed. The edge detection algorithms used for extraction of edge position from the measured profiles will be discussed for the types of instruments involved.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.