Abstract
Microwave hybrid heating (MHH) is a possible approach for soldering; yet, the long-term reliability of solder joints is still unclear. In this work, a comparative study was carried out on the influence of isothermal aging on SAC305/Cu solder joints by conventional reflow and MHH. The conventional reflow oven was set to 260 °C at 60 s holding time, and MHH was carried out at high operating power at 40 s. The reflowed sample was isothermally aged at 150 °C for various aging times (0, 240, 480 and 960 h) in a laboratory oven. The conventional reflow and MHH transformed the IMC structure from scallop-like to a planar-like Cu6Sn5 with a linear increase in thickness and a thin layer of Cu3Sn was observed at 240 h of aging. While Ag3Sn particles grew larger at longer aging time. The MHH shows a thinner Cu6Sn5 layer, and a smaller grain size compared to conventional reflow. The ultimate tensile strength (UTS) for conventional reflow (32.7 MPa) is 26.8% lower compared to MHH (44.7 MPa). The UTS for MHH is greater than conventional reflow as the isothermal aging time increases.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have