Abstract

This paper presents a comparative study of the heat transfer performance of lattice-structured heat sinks. Twenty different unit cells are chosen, and heat sinks are modeled in nTop with constant unit cell size. Al 6061 alloy is chosen as the material for analysis due to its good thermal conductivity, low weight, low cost, and high strength. Steady-state thermal analysis is performed using ANSYS with constant input parameters for all samples. Heat flux and temperature distribution within the heat sinks are analyzed. From the simulation, it was found that TPMS and plate-based heat sinks outperform other types with better heat transfer.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.