Abstract

We present in this paper the comparison of an electric double layer (DL) in argon helicon plasma and magnetized direct current (DC) discharge plasma. DL in high-density argon helicon plasma of 13.56 MHz RF discharge was investigated experimentally by a floating electrostatic probe and local optical emission spectroscopy (LOES). The DL characteristics at different operating parameters, including RF power (300–1500 W), tube diameter (8–60 mm), and external magnetic field (0–300 G), were measured. For comparison, DL in magnetized plasma channel of a DC discharge under different conditions was also measured experimentally. The results show that in both cases, DL appears in a divergent magnetic field where the magnetic field gradient is the largest and when the plasma density is sufficiently high. DL strength (or potential drop of DL) increases with the magnetic field in two different structures. It is suggested that the electric DL should be a common phenomenon in dense plasma under a gradient external magnetic field. DL in magnetized plasmas can be controlled properly by magnetic field structure and discharge mode (hence the plasma density).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.