Abstract
Jar testing and flow cytometry were used in conjunction with photometric dispersion analysis (PDA) to assess conventional alum coagulation with and without magnetic ion exchange (MIEX) pre-treatment for turbidity and bacterial removal capacity. Treatment assessment included powdered activated carbon (PAC) and pre-chlorination of the MIEX-treated raw water. Floc particles were subjected to shear forces after settling and re-suspended to gauge bacterial release potential, floc breakage and re-aggregation. MIEX in conjunction with alum coagulation achieved improved coagulation as measured by PDA but did not increase bacterial log removal value (LRV) in comparison with conventional coagulation. Pre-chlorination and PAC addition were seen to improve bacterial removal and coagulation, respectively, but were less effective for bacterial LRVs when they were used in conjunction during coagulation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.