Abstract

ObjectiveThe rapid development of artificial intelligence technologies for medical imaging has recently enabled automatic identification of anatomical landmarks on radiographs. The purpose of this study was to compare the results of an automatic cephalometric analysis using convolutional neural network with those obtained by a conventional cephalometric approach.Material and methodsCephalometric measurements of lateral cephalograms from 35 patients were obtained using an automatic program and a conventional program. Fifteen skeletal cephalometric measurements, nine dental cephalometric measurements, and two soft tissue cephalometric measurements obtained by the two methods were compared using paired t test and Bland-Altman plots.ResultsA comparison between the measurements from the automatic and conventional cephalometric analyses in terms of the paired t test confirmed that the saddle angle, linear measurements of maxillary incisor to NA line, and mandibular incisor to NB line showed statistically significant differences. All measurements were within the limits of agreement based on the Bland-Altman plots. The widths of limits of agreement were wider in dental measurements than those in the skeletal measurements.ConclusionsAutomatic cephalometric analyses based on convolutional neural network may offer clinically acceptable diagnostic performance. Careful consideration and additional manual adjustment are needed for dental measurements regarding tooth structures for higher accuracy and better performance.

Highlights

  • Cephalometric analysis is an essential diagnostic tool for the treatment planning and evaluation of orthodontic patients

  • A comparison between the measurements from the automatic and conventional cephalometric analyses in terms of the paired t test confirmed that the saddle angle, linear measurements of maxillary incisor to NA line, and mandibular incisor to NB line showed statistically significant differences

  • Automatic cephalometric analyses based on convolutional neural network may offer clinically acceptable diagnostic performance

Read more

Summary

Introduction

Cephalometric analysis is an essential diagnostic tool for the treatment planning and evaluation of orthodontic patients. Accurate identification of the anatomical landmarks on cephalograms is critical for a reliable cephalometric analysis [1]. Lateral cephalometric radiographs have been employed as an essential tool in orthodontics. Artificial intelligence (AI) refers to the study of systems that perform tasks that require human intelligence using different computerized algorithms [2, 3]. Machine learning is a method of data analysis that allows computer programs to automatically improve through cognitive content. It is a branch of technology that allows systems to learn from data, Jeon and Lee Progress in Orthodontics (2021) 22:14

Methods
Results
Conclusion