Abstract

The purpose of the present clinical study was to compare the Ricketts and Steiner cephalometric analysis obtained by two experienced orthodontists and artificial intelligence (AI)-based software program and measure the orthodontist variability. A total of 50 lateral cephalometric radiographs from 50 patients were obtained. Two groups were created depending on the operator performing the cephalometric analysis: orthodontists (Orthod group) and an AI software program (AI group). In the Orthod group, two independent experienced orthodontists performed the measurements by performing a manual identification of the cephalometric landmarks and a software program (NemoCeph; Nemotec) to calculate the measurements. In the AI group, an AI software program (CephX; ORCA Dental AI) was selected for both the automatic landmark identification and cephalometric measurements. The Ricketts and Steiner cephalometric analyses were assessed in both groups including a total of 24 measurements. The Shapiro-Wilk test showed that the data was normally distributed. The t-test was used to analyze the data (α = 0.05). The t-test analysis showed significant measurement discrepancies between the Orthod and AI group in seven of the 24 cephalometric parameters tested, namely the corpus length (p = 0.003), mandibular arc (p < 0.001), lower face height (p = 0.005), overjet (p = 0.019), and overbite (p = 0.022) in the Ricketts cephalometric analysis and occlusal to SN (p = 0.002) and GoGn-SN (p < 0.001) in the Steiner cephalometric analysis. The intraclass correlation coefficient (ICC) between both orthodontists of the Orthod group for each cephalometric measurement was calculated. Significant discrepancies were found in seven of the 24 cephalometric measurements tested between the orthodontists and the AI-based program assessed. The intra-operator reliability analysis showed reproducible measurements between both orthodontists, except for the corpus length measurement. The artificial intelligence software program tested has the potential to automatically obtain cephalometric analysis using lateral cephalometric radiographs; however, additional studies are needed to further evaluate the accuracy of this AI-based system.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call