Abstract

To evaluate a new enzyme immuno assay, Antigenz Chlamydia, for the detection of chlamydial antigen in urogenital samples using cell culture as the gold standard for comparison and direct immuno fluorescence to aid resolving the discrepancies. 212 men and 303 women attending an STD clinic and 404 women of child bearing age attending gynaecological clinics. Sensitivity, specificity, predictive value of positive result and predictive value of negative result of the new test were 77.6%, 99.0%, 94.3%, and 95.7% respectively in the high risk population with a prevalence of 16.5%. In the low risk population the figures were 84.2%, 94.5%, 43.2% and 99.2% respectively with a prevalence of 4.7%. Antigenz Chlamydia is an easy and quick test to perform. The test is suitable for use in high risk and low risk populations provided all positive samples are confirmed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.