Abstract
This paper presents the comparison between ultrasonic wave transmission (USWT) method and ultrasonic wave reflection (USWR) method in their ability to monitor the setting process of cement pastes. The velocity of ultrasonic longitudinal waves and shear wave reflection coefficient were measured simultaneously on cement pastes with different hydration kinetics. Even though both methods are able to reliably monitor the hydration process and formation of structure of an arbitrary cement paste, they monitor the setting process in different ways. The relationship between the velocity of longitudinal waves and shear wave reflection coefficient can be simplified into three characteristic phases and the end of the first phase can be used to define the beginning of the setting process of cement paste.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.