Abstract
Emerging three-dimensional digital visualization technology (DVT) provides more advantages than traditional microscopy in microsurgery; however, its impact on microsurgeons' visual and nervous systems and delicate microsurgery is still unclear, which hinders the wider implementation of DVT in digital visualization for microsurgery. Forty-two microsurgeons from the Zhongshan Ophthalmic Center were enrolled in this prospective self-controlled study. Each microsurgeon consecutively performed 30min conjunctival sutures using a three-dimensional digital display and a microscope, respectively. Visual function, autonomic nerve activity, and subjective symptoms were evaluated before and immediately after the operation. Visual functions, including accommodative lag, accommodative amplitude, near point of convergence and contrast sensitivity function (CSF), were measured by an expert optometrist. Heart rate variability was recorded by a wearable device for monitoring autonomic nervous activity. Subjective symptoms were evaluated by questionnaires. Microsurgical performance was assessed by the video-based Objective Structured Assessment of Technical Skill (OSATS) tool. Accommodative lag decreased from 0.63 (0.18) diopters (D) to 0.55 (0.16) D ( P =0.014), area under the log contrast sensitivity function increased from 1.49 (0.15) to 1.52 (0.14) ( P =0.037), and heart rate variability decreased from 36.00 (13.54) milliseconds (ms) to 32.26 (12.35) ms ( P =0.004) after using the DVT, but the changes showed no differences compared to traditional microscopy ( P >0.05). No statistical significance was observed for global OSATS scores between the two rounds of operations [mean difference, 0.05 (95% CI: -1.17 to 1.08) points; P =0.95]. Subjective symptoms were quite mild after using both techniques. The impact of DVT-based procedures on microsurgeons includes enhanced accommodation and sympathetic activity, but the changes and surgical performance are not significantly different from those of microscopy-based microsurgery. Our findings indicate that short-term use of DVT is reliable for microsurgery and the long-term effect of using DVT deserve more consideration.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.