Abstract
To compare the accommodative amplitude (AA), facility (AF), and lag between dominant and non-dominant eyes. Seventy students [mean (SD) age: 21.2 (1.7) years, range 18-25] from Zahedan University of Medical Sciences were selected. Retinoscopy and subjective refraction was used to determine the refractive error. The hole-in-the card method was used to determine eye dominance. The accommodative amplitude (AA) was measured in the dominant and non-dominant eye using the push-up method, and accommodative facility (AF) using ±2.00 dioptre flipper lenses at 40cm. Accommodative lag was determined using monocular estimate method (MEM) retinoscopy at 40cm. The right eye was dominant in 53 subjects (75.7%). There was no significant difference in refractive error (sphere, cylinder, and spherical equivalent) between dominant and non-dominant eyes. The mean (SD) for the AA, AF, and lag in dominant eyes was 12.48 (2.56) dioptres, 12.45 (4.83) cycles per minute, and 0.80 (0.27) dioptres respectively. The mean (SD) for the AA, AF, and lag in non-dominant eyes was 12.16 (2.37) dioptres, 12.20 (4.88) cycles per minute, and 0.83 (0.28) dioptres respectively. The mean (SD) difference in AA, AF, and lag between dominant and non dominant eyes was 0.32 (0.75) dioptres (P = 0.001), 0.25 (1.05) cycles per minute (P = 0.04), and -0.02 (0.11) dioptres (P = 0.10) respectively. The AA and AF was statistically better (P < 0.05) in the dominant eye group than in the non-dominant eye group. These data provided little evidence of any difference in the accommodative lag between dominant and non-dominant eyes (P > 0.05). The right eye was dominant in 76% of subjects. Superior AA and AF was found in the dominant eye as determined by hole-in-the card method in young healthy adults, although these differences are perhaps not of clinical significance (<0.50 dioptres and <2cycles per minute).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Graefe's Archive for Clinical and Experimental Ophthalmology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.