Abstract

This technical note summarizes a technical comparison of common testing procedures, as well as reviewed of the UN Test N` 5, for the assessment of the self-heating properties of cargoes and materials that has shown a clear trend on maritime fire and explosions events, as well as considering of external factors that can combine self-heating and emit flammable gases to conclude in an unlikely event affecting the security of crews and ships. A high understanding of the external factors effect on the cargo materials certainly will help the application of spontaneous reactions management actions (SRMA) on board of ships during the cargo sea passage. The intended comparison is based on laboratory, industry and field observations and data, whereas the among the external factors considered are, moisture content, stockpile procedure and aging, air velocities and moderate pressures internal and externally to the cargo material. The comparison results have shown that the self-heating and the flammable gas emissions has a common pattern when reacting with any oxygen available source, regardless the reactive material chemical composition.
 Keywords: reactive materials, self-heating, self-ignition, direct reduced iron fines, materials handling, UN test N` 5, maritime safety, spontaneous reactions, risk management. IMSBC Code , IMO.
 References
 [1]A. M. DeGennaro, M. W. Lohry, L. Martinelli, C. W. Rowley. Uncertainty Quantification for Cargo Hold Fires. Princeton University, Princeton, NJ, 08540, USA. American Institute of Aeronautics and Astronautics.
 [2]L.L.Sloss Assessing and Managing Spontaneous Combustion of Coals. IEA Clean Coal Center (CCC 259). Oct. 2015.
 [3].A. Janes, G Marlair, D Carson, j. Chaneausx. Towards the improvement of UN Test N1 5 Method for the characterization of substances which in contact with water emit Flammable Gases. Journal of Loss Prevention in the Process Industries. Elsevier 2012, 25 (3), pp 524-534.
 [4]G. Rouget, B. Majidi, D. Picard, G. Gauvin, D. Ziegler, J. Mashreghi, and H. Alamdar. Electrical Resistivity Measurement of Petroleum Coke Powder by Means of Four-Probe Method. Metallurgical and Materials Transactions B. Vol. 48B, Oct. 2017-2543.
 [5]Y. Rubiela Hernández Puerto, M.Triviño Restrepo. El coque metalúrgico aplicado a protección catódica (Metallurgia coque applied to catodic protection). Revista del Instituto de Investigaciones FIGMMG. Vol. 10, Nº 20, 60-67 (2007) UNMSM I.
 [6]S. Narayan Jha, K. Narsaiah, A.L. Basediya, R.Sharma, P. Jaiswal, R. Kumar, and R. Bhardwaj. Measurement techniques and application of electrical properties for nondestructive quality evaluation of foods—a review. Food Sci Technol. 2011 Aug; 48(4): 387–411.
 [7]R. Fontes Araujo, J. Batisa Zonta, E. Fontes Araujo, E. Heberle, E, F. Miranda Garcia Zonta. Teste de Conductividade Eletrica para Smentes de Feijao Mungo Verde 1. Rev. Brasikleira de Sementes, Vol. 33, N` 1, pp123/130, 2011.
 [8]P.A. Eidem. Electric Resistivity of Coke Beds. PhD Thesis. Norwegian University of Science and Technology Faculty of Natural Sciences and Technology Department of Materials Science and Engineering. Tronheim Oct. 2008.
 [9]N. Birks, et.al. - Mechanism in Corrosion Induced Auto-ignition of Direct Reduced Iron. Materials Science and Engineering Department, University of Pittsburgh.
 [10]Monitoring Implementation of the Hazardous and Noxious Substances Convention. Report on incidents involving HNS. Submitted by the United Kingdom. IMO 85th Session, Agenda item 5- LEG 85/INF.2, 19 September 2002.

Highlights

  • The ventilation requirements as described in the IMO IMSBC Code are briefly described in Section 3.4.2 clearly specifies that cargoes that may emit flammable gases in sufficient quantities to constitute a fire or explosion hazard should be effectively ventilated as necessary

  • 1.This research has proven he importance of considering the external factors on the reactivity of self-heating cargoes

  • Among these external factors the most important is considered to be the Direct Current (DC) important is the direct current (DC) energy supplied by the cathodic protection systems in either ships or metallic containers

Read more

Summary

I.INTRODUCTION

The ventilation requirements as described in the IMO IMSBC Code are briefly described in Section 3.4.2 clearly specifies that cargoes that may emit flammable gases in sufficient quantities to constitute a fire or explosion hazard should be effectively ventilated as necessary. Example of cargoes containing metals that emit flammable gases after in contact with water listed in the IMSBC Code are: Aluminum Ferrosilicon Powder forms, Aluminum Smelting By-products or Aluminum Remelting By-products UN 3170, Ferro phosphorus (including briquettes), Ferrosilicon UN 1408, Magnesium powders, Silicon-manganese (low carbon), Zinc Ashes UN 1435, Direct Reduced Iron Fines, pellets and lumps. These cargoes that require ventilation are listed among others of nonmetallic content such as grains, coal, seed cake etc.

Seed cake