Abstract
The paper presents and compares the results on the reliability and remaining life assessment of a reactor (coxing box) from a petrochemical plant. The reactor shell is made of 16Mo5 (W1.5423) steel, with a thickness of 25 mm, plated with 3 mm thick X6CrAl13 (W1.4002) stainless steel. The assessment was made in two steps. For preliminary remnant life assessment, specifications of section VII of the ASME code was used followed by iRiS‑Thermo expert system. Further, experimental creep and metallographic replica analysis were performed. Results comparison of the two methods applied revealed a reduction of the preliminary estimated remaining live obtained using metallographic replica analysis. Based on the results obtained, the possibility to extend the service duration of the coxing box in the safety condition, using current process parameters, with of 20.000 hours was highlighted.