Abstract

For detection of subsurface defects, flash thermography results are often evaluated by selecting the thermal image with the largest contrast between the sound and defective area. Another possibility is to calculate the logarithmic derivatives of the thermal signal, and evaluate the 1st or 2nd derivative images. In this paper, it is investigated how the contrast in these images depend on the defect size and defect depth. Analytical calculations and FEM simulations are presented, and based on these results equations for the contrast maxima are derived. Several advantages of the derivative images are shown; for example a defect with an aspect ratio around unity can be reliably detected in the derivative image, but not in the thermal image. To demonstrate these results experimental data are also presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.