Abstract
The binding of six trace metals, Mn(II), Ni(II), Zn(II), Cu(II), Cd(II) and Fe(III), to human cord serum has been studied by Sephadex G-100 gel filtration at physiological pH, using radioisotopes as tracers. The results are compared with those obtained from adult serum. In both cord and adult sera, extensive amounts of the metals are bound to high molecular weight proteins. Among them, Fe(III) is mostly bound to transferrin; Ni(II), Zn(II), Cu(II), and Cd(II) are bound to albumin and other macromolecules. The binding of Mn(II) either to transferrin or albumin is not resolved. Small fractions of Zn(II), Cu(II), and Cd(II) and large fractions of Mn(II) and Ni(II) are found to be associated with low molecular weight components of both sera. The distribution varies from metal to metal. However, the low molecular weight component of the size 1500 - 10000 is present in all the metals studied. Further purification of this component was attempted by DEAE-cellulose ion-exchange chromatography. The possible identity as well as the biological role played by this particular component of serum in the transport of metals in blood and across membranes is discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.