Abstract
The core objective of this study is to identify the cost effective seismic retrofitting option for multi-story unreinforced masonry (URM) buildings. A seismically deficient 3 story URM structure assumed to be located in the moderate seismic zone of Bangladesh is taken as a reference for this work. Depending on the expected seismic performance level, 5 possible retrofitting schemes are designed for the building and then compared in terms of cost of construction. It is evident from the study that, the ‘Splint and Bandage’ and the ‘Internal Concrete Box’ are the cheapest solutions considering ‘Life Safety’ and ‘Immediate Occupancy’ performance level respectively. Expensive retrofitting options like ‘Seismic Isolation’ and ‘Internal Concrete Box’ have added advantage to withstand multiple earthquake events over the cheaper methods such as ‘Splint and Bandage’ and ‘jacketing’.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.