Abstract

Aim. To assess clinical and hemodynamic outcomes of aortic valve replacement with xenoaortic biological prosthesis “Aspire Vascutek” and xenopericardial biological prosthesis “UniLine”. Methods. 130 patients who underwent aortic valve replacement with bioprostheses in the period from October 2012 to March 2016 were included in the study. All patients were enrolled into two groups according to the model of the implanted device. 65 recipients of xenoaortic bioprostheses “Aspire Vascutek” were included in Group 1, whereas patients (n = 65) xenopericardial bioprostheses “UniLine” were assigned in Group 2. Males prevailed in Group 1 (63%, the mean age - 66.4±5.5 years). 85% of Group 1 patients had heart failure Strazhesko-Vasilenko IIA grade and 94% of patients had chronic heart failure NYHA III. Similarly, male patients (58%) prevailed in Group 2. The mean age of Group 2 patients was 66.5±3.65 years. All patients in Group 2 II had heart failure Strazhesko-Vasilenko IIA grade and chronic heart failure NYHA III. Results Two patients in Group 1 died in the early postoperative period (the overall mortality was 1.5%). All patients had chronic heart failure NYHA I-II at discharge. Peak transvalvular pressure gradient significantly decreased in the in-hospital period, particularly in Group 2 patients (82,3±22,7 mm Hg vs. 28.8±7.6 mm Hg). 88% of Group 1 patients underwent the 60-month follow-up, and 96% of Group 2 patients - the 48-month follow-up. Transvalvular pressure gradients decreased progressively in both study groups within 60 months follow-up. This decrease was more pronounced in recipients of xenopericardial biological prostheses. Conclusion. Aortic valve replacement with xenopericardial bioprostheses “UniLine” and xenoaortic bioprostheses “Aspire Vascutek” for aortic valvular disease allows treating intracardiac hemodynamic derangements and achieving good clinical and hemodynamic outcomes.

Highlights

  • Проанализированы непосредственные и отдаленные результаты имплантации каркасных ксеноаортальных и ксеноперикардиальных биологических протезов при коррекции дегенеративных пороков аортального клапана

  • 130 patients who underwent aortic valve replacement with bioprostheses in the period from October 2012 to March 2016 were included in the study

  • Males prevailed in Group 1 (63%, the mean age - 66.4±5.5 years). 85% of Group 1 patients had heart failure Strazhesko-Vasilenko IIA grade and 94% of patients had chronic heart failure NYHA III

Read more

Summary

Результаты Заключение Ключевые слова

Исследование клинических и гемодинамических результатов имплантации ксеноаортального биологического протеза (БП) «Aspire» (Vascutek Terumo, Великобритания) и ксеноперикардиального биологического протеза «ЮниЛайн» (НеоКор, Кемерово, РФ) для коррекции пороков аортального клапана. В группу I вошли 65 пациентов, которым для коррекции аортального порока использовался ксеноаортальный БП «Aspire». В группе I преобладали мужчины (63%, средний возраст - 66,4±5,5 лет). 85% пациентов в группе I имели НК IIA по Стражеско – Василенко и 94% пациентов находились в III ФК по NYHA. Все наблюдаемые пациенты в группе II имели НК II A по классификации Стражеско – Василенко и находились в III ФК по NYHA. На госпитальном этапе отмечалось достоверное снижение трансклапанных пиковых градиентов давления, наиболее выраженное у пациентов в группе II: с 82,3±22,7 мм рт. После операции наблюдением было охвачено 88% пациентов в группе I; в сроки до 48 мес. При оценке трансклапанных градиентов давления в сроки до 60 мес. Поступила в редакцию: 03.03.18; поступила после доработки: 07.05.18; принята к печати: 16.05.18

FOR DEGENERATIVE AORTIC VALVULAR DISEASE
Conclusion Keywords
Список сокращений
ГСД пик
Конфликт интересов
Information about authors
Authors contribution
Findings
СПИСОК ЛИТЕРАТУРЫ
Full Text
Published version (Free)