Abstract

The integrity of the femoral bone is crucial when considering reconstructive options for the first-time revision of a total hip arthroplasty (THA). Aseptic loosening of primary stems, whether cemented or uncemented, significantly affects the volume and quality of resultant femoral bone loss. This study evaluates the impact of the initial fixation method on femoral bone defect patterns by comparing the extent of bone loss. A retrospective cohort of 215 patients with either cemented or uncemented stems, indicated for aseptic stem loosening, and undergoing first-time stem revision from 2010 to 2022 at our institution was analyzed. Femoral bone loss extent at first-time revision was preoperatively gauged using radiographs and categorized by the Paprosky classification. Survival probabilities pre-first-time revision for both stem types were calculated using Kaplan-Meier methods. Hazard ratios were applied to compare the risk of initial revision for uncemented versus cemented stems within the first and subsequent 2nd to 10th years post-primary implantation. Cemented stems were associated with a higher occurrence of significant bone defects of type 3a (23.53% vs. 14.02%, p = .108), 3b (39.22% vs. 1.22%, p < .001), and 4 (3.92% vs. 0.00%) compared to uncemented stems. Conversely, smaller defects of type 1 and 2 were more prevalent in uncemented stem loosening (84.76% vs. 33.33%, p < .001). Notably, cemented stems exhibited a significantly prolonged revision-free period over the complete decade following primary insertion (p < .001). The unadjusted risk of first-time revision due to stem loosening showed a tendency to an increase in uncemented stems within the initial postoperative year (HR 5.55, 95% CI 0.74; 41.67, p = .096), and an adjusted risk of 2.1 (95% CI 0.26; 16.53, p = .488). However, these differences did not reach statistical significance. In the subsequent 2nd-10th years, the risk was lower compared to cemented stems (HR 2.35, 95% CI 1.39; 3.99, p = .002). Uncemented primary stems necessitating first-time revision due to aseptic loosening demonstrated notably smaller femoral bone defects in comparison to primary cemented stems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.