Abstract

A recent paper by M. Zaky & M. Metwaly (doi: 10.1109/TPEL.2016.2583660) proposed a fuzzy logic controller (FLC) to mitigate the negative effects of motor parameter variation influence on indirect rotor field oriented control (IRFOC) without proposing a tuning method. However, neither rotor nor magnetizing inductances were investigated. Instead, the variation in stator resistance and load inertia—which have less effect on the orientation algorithm—is demonstrated. This correspondence introduces a typical system model with similar simulation platform and parameters. With identical tests, two errors to the original paper have been found. First, the reported speed which is in rev/min should be in rad/s. Second, the motor speed response to increasing inertia is opposite. The obtained results from the evaluation model confirm the claimed issues which conflict with the interpretations of the commented paper results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.