Abstract
ABSTRACTOzone, ultrasound, and ozone/ultrasound processes were evaluated for the removal of 1,4-dioxane from tap water using a continuous flow reactor with on-line aqueous ozone measurement. The addition of ultrasound to ozone was found to significantly boost removal. The removal of 1,4-dioxane by ozone/ultrasound process exceeded the sum of the removals from ozone alone and ultrasound alone. Ultrasound alone showed less than 20% removal of 1,4-dioxane. The effects of reactor pressurization and bicarbonate as a hydroxyl radical scavenger were also studied. It was observed that at constant aqueous ozone concentration, additional pressure in the reactor tended to mute the 1,4-dioxane removal boost noted in the ozone/ultrasound process, while additional pressure did not affect 1,4-dioxane removal via ozone alone. The removal of 1,4-dioxane was found to be dependent on the consumption of aqueous ozone, and the consumption of ozone was found to be increased by either the addition of ultrasound or by increasing...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Ozone-science & Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.