Abstract

This enzyme immunoassay for specific measurement of secretory immunoglobulin A concentrations in human serum involves use of a small chromatographic column as a solid-phase. Serum samples are incubated for 2 h with beta-D-galactosidase-labeled antibody to secretory component, then passed through a 0.1-mL Sepharose 4B column containing antibodies to human immunoglobulin A. After the column is washed to remove the unbound label, the buffer in the column is replaced by a solution of o-nitrophenyl-beta-D-galactoside (a beta-D-galactosidase substrate) and incubated at 25 degrees C overnight. The enzyme reaction is stopped by washing the column with sodium carbonate solution, and the absorbance of the eluate is measured at 420 nm. The concentration of secretory immunoglobulin A can be determined with a minimum detectable sensitivity of 3 mg/L, without interference from free immunoglobulin A and secretory component in the same samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.