Abstract

The co-combustion of dry coal and sludge was carried out in a self-built laboratory scale fluidized bed furnace. We used FTIR spectroscopy, high-resolution gas chromatography, high-resolution mass spectrometry, and XRF to capture and dynamically observe the flue gas fly ash and bottom ash. The sludge sample was taken from a municipal sewage treatment plant and its mixing ratio was below 20%. The temperature distribution of the furnace was observed and the emissions of the main gaseous pollutants such as SO2, NOx, and dioxins were measured in the combustion process. The heavy metal contents of fly ash and bottom ash were later detected to analyze the migration characteristics. The results showed that all of the gaseous pollutants measured increased linearly with the sludge mixing ratio. However, it could also meet the 1 metal content of bottom ash and fly ash did not change much. Through the elaboration of the above points, this study can provide guidance for future research on the co-combustion of coal boiler sludge and suggest favorable conditions for the co-combustion of coal boiler sludge.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call