Abstract

The aim of this study was to evaluate the utility of Tc-ubiquicidin (Tc-UBI) (29-41) as an adjunct to an methylene diphosphonate (MDP) bone scan in differentiating septic versus aseptic loosening in patients with painful prosthesis posted for revision surgery. A two-vial cold kit of UBI (29-41) was prepared and utilized for the preparation of patient dose of Tc-UBI (29-41). Twenty two patients with painful hip or knee prosthesis and scheduled for revision surgery were included in the study. Overall, 370-555 MBq of Tc-UBI (29-41) was injected intravenously in all the patients. A blood pool image at 20 min after injection was followed by spot views of the suspected region of infection (target) and a corresponding normal area (nontarget) at 60 min. All patients underwent a routine Tc-MDP three-phase whole-body bone scan, followed by single-photon emission computed tomography/computed tomography of the prosthesis within a week of the Tc-UBI (29-41) study. For Tc-UBI scans, a visual score (0-3) was used to categorize studies as positive or negative, with scores of 0 (minimal or no uptake; less than soft tissue or contralateral extremity) and 1 (mild; equivalent to soft tissue or contralateral extremity) being considered negative and scores of 2 (moderate; uptake greater than soft tissue or contralateral extremity, but less than the liver) or 3 (intense; uptake greater than soft tissue or contralateral extremity and equivalent to the liver) being considered positive. The final correlation was on the basis of bacterial culture as the major criterion and the results of clinical tests, radiography, fluorine-18-fluorodeoxyglucose PET-CT, and three-phase bone scanning as the minor criteria. In all, 22 studies were carried out with Tc-UBI (29-41). Of these, 16 scans were considered positive and six were negative for infection foci. All negative scans were subsequently confirmed to be true negative. Adverse reactions were not observed during image acquisition and within 5 days after the study. The overall sensitivity, specificity, and positive and negative predictive values were 100, 85.7, 93.75, and 100%, respectively. A combination of an MDP bone scan and UBI scans was considered to yield maximum confidence toward reporting for the presence of infection. Patient dose of Tc-UBI (29-41) was prepared successfully and a simple quality control method to check radiolabeling yield was used at the hospital radiopharmacy. Tc-UBI (29-41) showed promise in localizing foci of infection, with optimal visualization at 20-60 min, for the evaluation of prosthesis loosening.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.