Abstract

Objective To study the materials satisfaction rate,complication rate and influencing factors of ultrasound-guided fast batch percutaneous one-needle kidney biopsy.Method The materials satisfaction rate and complication rate of 710 cases of ultrasound-guided fast batch percutaneous kidney biopsy were analyzed retrospectively.Results The materials satisfaction rate of 710 cases of renal biopsy was 99.4%,without significant difference between one-needle biopsy and two or three-needle biopsy.The materials satisfaction rate of special crowd was near to 100%,total complication rate was 17.5%,10.7% of low back and waist pain,5.5% of transient hematuria,3.7% of perirenal hematoma,0.3% of serious bleeding hematoma.No perirenal hematoma or serious bleeding hematoma was found in special crowd.Risk factors analysis suggested one-needle biopsy reduced the risk of complications of hematuria.Conclusion Fast batch kidney biopsy has good materials satisfaction rate and low complication rate. Key words: Ultrasound-guided; Kidney Biopsy; Successful rate; Complication

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call