Abstract

Border molding of the custom tray's edge is an important stage in the treatment of an edentulous jaw that determines the stability of prosthesis at rest and function. Solid, thermoplastic and silicon impression materials may be used in border molding. After bolder molding procedure, the negative pressure between the custom tray and the prosthetic field is created. This is an informal indication for a good impression. To compare the negative pressure created after border molding procedure with different impression materials. 35 patients (17 men and 18 women) aged 51 to 87 years with a complete edentulous upper jaw were examined. New clinical method for negative pressure measurement was created. We used a special custom tray with palatal adaptor and a pump. Two groups of impression materials were tested: thermoplastic (Kerr impression compound green sticks, GC Iso functional sticks) and silicones (Detaseal function, Sta-seal f). Statistical analysis was performed using ANOVA, confirmed by the absolute value analysis used to compare negative results, and a log transformation analysis for greater precision and also for negative data comparison. A statistically significant difference was found between the two thermoplastic materials - GC Iso functional sticks and Impression compound green sticks. The mean group difference between these materials was 0.049 bars. There was no statistically significant difference between the other groups of materials. Quantitative measurement of negative pressure, created between the custom tray and the prosthetic field is entirely possible under clinical conditions.

Highlights

  • Border molding of the custom tray’s edge is an important stage in the treatment of an edentulous jaw that determines the stability of prosthesis at rest and function

  • To compare the negative pressure created after border molding procedure with different impression materials

  • The working time is 5-6 min., which is absolutely enough for border molding procedure

Read more

Summary

Introduction

Border molding of the custom tray’s edge is an important stage in the treatment of an edentulous jaw that determines the stability of prosthesis at rest and function. The negative pressure between the custom tray and the prosthetic field is created. This is an informal indication for a good impression. Aim: To compare the negative pressure created after border molding procedure with different impression materials. Results: A statistically significant difference was found between the two thermoplastic materials – GC Iso functional sticks and Impression compound green sticks. The functional pressure technique is a successful solution to the problems with harmful pressure and incorrect impressing of the border zones.[1] Selective pressure concept is invented by Boucher in 1950.

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.